Lifecycle and recovery

Await initialise() before sending or receiving. It clears the endpoint’s state, outputs, and previous faults. Reset the DUT separately.

Endpoint

Owned signals

Source

data, valid, last, and bound sidebands

Sink

ready, when present

Without a monitored reset pin, initialisation clears at a falling edge. The source clears valid, last, and bound sidebands to zero, and calls the payload adapter’s clear(). HandlePayload clears every payload leaf to zero; custom adapters define their own recovery values and can raise during clearing. The sink clears ready, queued transfers, and incomplete packets. It never calls the adapter’s clear(). Without ready or reset monitoring, capture starts when initialisation completes.

If you initialise during traffic, reset or drain the DUT and coordinate with the peer before starting another packet.

Reset-pin monitoring

To monitor an active-high reset pin, bind it when constructing the endpoint:

source = AxiStreamSource(
	bus,
	clock=dut.clk,
	reset="my_reset",
	reset_active_high=True,
)

Choose the polarity explicitly; the default is active-low. The pin must be mutable one-bit logic and separate from the clock and stream signals. initialise() samples the pin after writes for the current simulator time step settle. Any sampled value other than literal 0 or 1 latches ProtocolValueError. The call clears the endpoint’s outputs and returns without waiting for reset release or a clock edge.

Assertion invalidates pending work, stops capture, discards queued transfers and incomplete packets, and clears owned outputs at the first writable opportunity, including while the clock is stopped. If observed in ReadOnly, clearing is deferred by one simulator step.

The endpoint waits through these edges after release:

Edge

Endpoint state

R0

First rising edge sampling the inactive pin

R1

Following rising edge; traffic still disabled

F1

Falling edge after R1; endpoint becomes available

R2

Earliest transfer through the re-enabled endpoint

The caller must deassert reset synchronously after a rising edge. The interval follows Arm IHI 0051B §2.8.2 for the chosen polarity. Reasserting reset restarts the interval.

A healthy endpoint resumes after release, including capture without ready. Calls during assertion or release raise EndpointStateError. The endpoint keeps reporting a previous fault until initialise() or close().

The release interval applies even when the pin is already inactive at setup. In code that previously sent or received immediately after initialise() with a reset pin, add await endpoint.wait_available() before that first transfer. If the same task controls reset, deassert it before waiting. The wait is optional: once the interval ends, transfers work automatically. An early send or receive raises EndpointStateError without queuing a transfer. wait_available() can block while reset is asserted or the clock is stopped. Cancelling the wait leaves the endpoint unchanged.

See Start and recover with a reset pin.

Cancelling initialise() leaves reset monitoring active to clear outputs on assertion. Call initialise() again before starting traffic.

Errors and cancellation

Argument checks before a transfer leave the endpoint usable. If an operation fails after it starts, or you cancel it, call initialise() before starting another. On cancellation, the outputs keep their driven values until initialisation, close(), or reset assertion clears them.

Check what the peer accepted before retrying. An operation can be interrupted after acceptance and before it returns. Use a scoreboard or reset both ends to avoid sending a transfer twice.

Initialisation, pin assertion, and close() interrupt active operations with coaxi.TransferReset. An invalid reset or recorded fault can instead report that fault. Catch expected interruption inside spawned coroutines:

import cocotb
from cocotb.triggers import Timer
from coaxi import TransferReset


async def receive_until_interrupted() -> None:
	try:
		await sink.recv()
	except TransferReset:
		pass


receiving = cocotb.start_soon(receive_until_interrupted())
await Timer(100, unit="ns")
await sink.initialise()
await receiving

The snippet assumes an initialised sink and a running clock. Cocotb can fail a test on an unobserved task exception before a later await observes it. Handle other expected faults inside the task as appropriate.

Concurrent transfer operations on one endpoint, unavailable endpoints, and overlapping initialise() and close() calls raise coaxi.EndpointStateError. Invalid bindings raise coaxi.SignalBindingError. See Errors for the remaining exception contracts.

Closing

close() stops reset monitoring, capture, and pause sampling. It discards queued state, faults, and the pause pattern, and invalidates active operations. A source or sink with ready clears its outputs at a falling edge. A sink without ready closes immediately. Repeated closes are safe.

A failed or cancelled close leaves the endpoint closed, but output cleanup may be incomplete. Explicit initialise() starts it again.

Enable DEBUG on coaxi.stream to log transfers, framing, initialisation, and reset.